Raised Floor Optimization

It is a large expense to add additional air conditioning capacity to the data center.  With the increase in heat demands, it has become imperative to maximize the efficiency of your existing room air conditioning.  These relatively low cost and simple solutions which we offer can yield huge efficiency gains.  Count on Data Center Resources to help you keep your cool.

> Cold Aisle Containment
Cold Aisle Containment enables an existing cooling infrastructure to support higher heat loads and/or significantly improve cooling efficiency. The concept is to lock in the cool air delivered from CRAC where it is needed most, at the server intake.  It also eliminates re-circulation from hot aisle.

Cold Aisle Containment Strips - Cool Shield 

Improve Efficiency 40+%Maximize Existing Cooling Capacity
Target Cooling for Higher Density or Hot Spots Installs Around Existing Server Cabinets
More Information
> High Air Flow Floor Tiles
Most data centers use perforated tiles to direct cooled air from the subfloor to the front of equipment racks.  Higher density racks may require a higher volume of cool air than traditional tiles can deliver.  High air flow floor tiles allow more for this greater air flow.  Use in areas where cooling needs a boost.

Over 1000 CFM of Air Flow More than Double Air Flow vs. Traditional Perf Tiles
Works with All Floor Tile Manufacturers Use Wherever Greater Air Flow is Needed
More Information
> Floor Grommets
Sealing the cable openings in raised flooring may not seam like a big priority, however, it can make a dramatic improvement in your cooling efficiency.  Cool air escaping from cut-outs reduces the under floor pressure which means less air flow from perforated tiles to cool your servers.

 

Seals Cable Openings  Increase Cooling Efficiency
Positive ROI Maximize Existing Cooling
More Information
> Blanking Panels
Most likely the most simple and cost effective method for improving air flow efficiency is the use of blanking panels to fill unused "U" positions in rack or enclosure.  They help keep the cool air at the front of cabinet where servers intake air.

Keeps Cool Air At the Front of Cabinets Helps Get Cool Air to Higher "U" Positions
High ROI Quick Install Models
More Information

 


Enhanced Cooling Info Request

    Send Information On:       

 Floor Grommets
 Blanking Panels
 High Flow Floor Tiles
 Cabinet Exhaust Ducts
 Aisle Containment
 Under Floor Partitions
 Cabinet Fan Systems
 Portable AC Units

    Notes     

 

   Your Email Address   




Control Room Solutions

Console Furniture

LCD Furniture

CRT Furniture

Sit/Stand Console Furniture

Network Furniture
Video Displays

Video Cube Walls

Large Displays

Video Processors

 

Trade Memberships

 

 

Total Solutions.  One Resource.
(Toll Free) 866.740.2121    (Direct)239.949.0514    (Fax)866.550.1135

Email Us
Copyright©2007 Data Center Resources, LLC  All Rights Reserved

 

a